logo m2m do Brasil sistemas de ultrassom phased array para ensaios não destrutivos END
M2M ndt France phased-array technologies for non destructive testing NDT


M2M
 
tecnologia em phased-array

Tube inspection using massively parallel systems

 
The objective of the NDT procedure is to detect defects from the outside of the tube at very high speed. Known defects include loss of thickness, delaminations, and cracks (see figure below). The following schematic diagram illustrates the location and orientation of these defects.
 
tube defects

In order to meet speed requirements, several inspection techniques are used in parallel rather than fired sequentially. NDT procedures are decomposed into:

The full inspection procedure is illustrated in the following schematic diagram:

fast tube inspection using phased arrays M2M NDT


The customer’s speed requirements are achieved by making all measurements for the tube inspection simultaneously using three fully parallel systems: one MULTIX64 and two MULTIX128. This customized inspection system has been successfully implemented at the customer’s production site (see pictures below).

CEV VALOUREC DMV

On-site implementation. Pictures show display-screen (left-hand photo), probes and coupling to the tube (top-left photo). The helicoidal motion controller is shown in the bottom-right picture. Work realized in collaboration with DMV (group Mannesmann) and CEV (VALLOUREC R&D Group).

Download